Product info   
Search
Your location£ºhome > News > Product info >

6SE7136-0EE62-3BA0

2016-04-21 10:08      Click£ºtimes
MLFB            
SIMOVERT MASTERDRIVES CONVERTER CABINET UNIT, IP20      
3 AC 380-480V, 50/60Hz WITH 6 PULSE INCOMING SUPPLY      
6SE7131-0EB61-3BA0 92A 45kw        
6SE7131-2EC61-3BA0 124A 55kw        
6SE7131-5EC61-3BA0 146A 75kw        
6SE7131-8EC61-3BA0 186A 90kw        
6SE7132-1ED61-3BA0 210A 110kw        
6SE7132-6ED61-3BA0 260A 132kw        
6SE7133-2ED61-3BA0 315A 160kw        
6SE7133-7ED61-3BA0 370A 200kw        
6SE7135-1EE62-3BA0 510A 250kw        
6SE7136-0EE62-3BA0 590A 315kw        
6SE7137-0EE62-3BA0 690A 400kw        
6SE7138-6EG62-3BA0 860A 500kw       EURO 62,400
6SE7141-1EH62-3BA0 1100A 630kw        
6SE7141-3EJ62-3BA0 1300A 710kw        
SIMOVERT MASTERDRIVES CONVERTER CABINET UNIT, IP20      
3 AC 660-690V, 50/60Hz WITH 6 PULSE INCOMING SUPPLY      
6SE7132-1HD61-3BA0 208A 200kw        
6SE7133-0HE62-3BA0 297A 250kw        
6SE7133-5HE62-3BA0 354A 315kw        
6SE7134-5HE62-3BA0 452A 400kw        
6SE7135-7HG62-3BA0 570A 500kw       EURO 64,400
6SE7136-5HG62-3BA0 650A 630kw       EURO 70,600
6SE7138-6HG62-3BA0 860A 800kw        
6SE7141-1HJ62-3BA0 1080A 1000kw        
6SE7141-2HJ62-3BA0 1230A 1200kw        
6SE7141-4HL62-3BA0 1400A 1300kw        
6SE7141-6HL62-3BA0 1580A 1500kw        
SIMOVERT MASTERDRIVES CONVERTER CABINET UNIT, IP20      
3 AC 380-480V, 50/60Hz WITH 12 PULSE INCOMING SUPPLY      
6SE7135-1KJ62-3BA0 510A 250kw        
6SE7137-0KJ62-3BA0 690A 400kw        
6SE7138-6KJ62-3BA0 860A 500kw        
6SE7141-1KL62-3BA0 1100A 630kw        
6SE7141-3KM62-3BA0 1300A 710kw        
SIMOVERT MASTERDRIVES CONVERTER CABINET UNIT, IP20      
3 AC 380-480V, 50/60Hz WITH 6 PULSE INCOMING SUPPLY, WITH REGENERATIVE FEEDBACK
6SE7131-0EE61-4BA0 92A 45kw        
6SE7131-2EE61-4BA0 124A 55kw        
6SE7131-5EE61-4BA0 146A 75kw        
6SE7131-8EE61-4BA0 186A 90kw        
6SE7132-1EE61-4BA0 210A 110kw        
6SE7132-6EE61-4BA0 260A 132kw        
6SE7133-2EE61-4BA0 315A 160kw        
6SE7133-7EE61-4BA0 370A 200kw        
6SE7135-1EF62-4BA0 510A 250kw        
6SE7136-0EG62-4BA0 590A 315kw        
6SE7137-0EG62-4BA0 690A 400kw        
6SE7138-6EG62-4BA0 860A 500kw        
6SE7141-1EH62-4BA0 1100A 630kw        
6SE7141-3EJ62-4BA0 1300A 710kw        
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
OPERATOR CONTROL PANELS AND ADAPTER BOARDS      
K01, K02 Adapter board ADB, plugged in position 2, 3    
K08 OP1S, with OP1S operator control panel on cabinet door  
K11 LBA, local bus adapter for the electronic box    
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
TECHNOLOGY BOARDS          
K30 TSY, digital tachometer and synchronising board    
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
EXPANSION BOARDS            
G61/63/64/65/66/67 Terminal extension board EB1, plugged in slot A/C/D/E/F/G  
G71/73/74/75/76/77 Terminal extension board EB2, plugged in slot A/C/D/E/F/G  
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
INTERFACE BOARDS AND AUXILIARY POWER SUPPLY UNITS      
K20 Serial interface board SCB1      
K21 Serial interface board SCB2      
K41 Serial interface board SCI1, for analog and binary signals  
K42 Serial interface board 2*SCI1, for analog and binary signals  
K50 Interface board DTI, for digital tachometer    
K51 DTI for T300, for digital tachometer      
K60 Interface board ATI, for analog tachometer    
K73 Power supply, 230V AC-24V DC      
K74 Power supply, 380V AC-230V AC      
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
COMMUNICATION BOARDS          
C11/13/14/15/16/17 Pulse generator board SBP, plugged in slot A/C/D/E/F/G    
G11/13/15/17 Communication board Profibus CBP, plugged in slot A/C/E/G  
G21/23/25/27 Communication board CAN-BUS CBC, plugged in slot A/C/E/G  
G41/43/44/45/46/47 Communication board SIMOLINK SLB, plugged in slot A/C/D/E/F/G  
G91/93/95/97 Communication board Profibus CBP2, plugged in slot A/C/E/G  
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
ISOLATION AMPLIFIERS FOR ANALOG INPUTS AND OUTPUTS    
E06 Analog output1, -10V to +10V / -10V to +10V    
E07 Analog output2, -10V to +10V / -10V to +10V    
E16 Analog output1, -10V to +10V / -20mA to +20mA    
E17 Analog output2, -10V to +10V / -20mA to +21mA    
E26 Analog output1, 0V to +10V / 4mA to +20mA    
E27 Analog output2, 0V to +10V / 4mA to +21mA    
E46 Analog input1, 0(4)mA to 20mA / 0(4)mA to 20mA    
E47 Analog input2, 0(4)mA to 20mA / 0(4)mA to 20mA    
E56 Analog input1, -10V to +10V / -10V to +10V    
E57 Analog input2, -10V to +10V / -10V to +10V    
E66 Analog input1, -20mA to +20mA / -10V to +10V    
E67 Analog input2, -20mA to +20mA / -10V to +10V    
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
RADIO INTERFERENCE SUPPESSION FILTER        
L00 For converter cabinet, 6 pulse, 132kw      
L00 For converter cabinet, 6 pulse, 45kw      
L00 For converter cabinet, 6 pulse, 55kw      
L00 For converter cabinet, 6 pulse, 75kw      
L00 For converter cabinet, 6 pulse, 90kw      
L00 For converter cabinet, 6 pulse, 160kw      
L00 For converter cabinet, 6 pulse, 200kw      
L00 For converter cabinet, 6 pulse, 250kw      
L00 For converter cabinet, 6 pulse, 315kw      
L00 For converter cabinet, 6 pulse, 400kw      
L00 For converter cabinet, 6 pulse, 500kw      
L00 For converter cabinet, 6 pulse, 110kw      
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
OUTPUT REACTOR IRON CORE          
L08 For converter cabinet, 6 pulse, 90kw      
L08 For converter cabinet, 6 pulse, 500kw      
L08 For converter cabinet, 6 pulse, 400kw      
L08 For converter cabinet, 6 pulse, 315kw      
L08 For converter cabinet, 6 pulse, 250kw      
L08 For converter cabinet, 6 pulse, 200kw      
L08 For converter cabinet, 6 pulse, 160kw      
L08 For converter cabinet, 6 pulse, 110kw      
L08 For converter cabinet, 6 pulse, 75kw      
L08 For converter cabinet, 6 pulse, 55kw      
L08 For converter cabinet, 6 pulse, 45kw      
L08 For converter cabinet, 6 pulse, 132kw      
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
OUTPUT REACTOR FERRITE CORE          
L09            
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
VOLTAGE LIMITING FILTER (DV/DT)        
L10            
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
SINUSOIDAL FILTER            
L15            
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
ADDITIONAL CONTROL FUNCTIONS        
L13 For converter cabinet, 6 pulse, 250kw      
L13 For converter cabinet, 6 pulse, 710kw      
L13 For converter cabinet, 6 pulse, 630kw      
L13 For converter cabinet, 6 pulse, 500kw      
L13 For converter cabinet, 6 pulse, 45kw      
L13 For converter cabinet, 6 pulse, 315kw      
L13 For converter cabinet, 6 pulse, 200kw      
L13 For converter cabinet, 6 pulse, 160kw      
L13 For converter cabinet, 6 pulse, 132kw      
L13 For converter cabinet, 6 pulse, 110kw      
L13 For converter cabinet, 6 pulse, 90kw      
L13 For converter cabinet, 6 pulse, 75kw      
L13 For converter cabinet, 6 pulse, 55kw      
L13 For converter cabinet, 6 pulse, 400kw      
L41 Terminal strip for binary inputs and outputs    
L42 Terminal strip for analog inputs and outputs    
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
BRAKING UNITS (INTEGRATED IN CABINET)        
L64 10kw          
L67 20kw          
L71 50kw          
L74 100kw          
L77 170kw          
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
BRAKING RESISTORS (SUPPLIED SEPARATELY)      
C64 10kw          
C67 20kw          
C71 50kw          
C74 100kw          
C77 170kw          
SIMOVERT MASTERDRIVES CABINET BUILT-IN OPTIONS      
MECHANICAL COMPONENTS AND OPTIONS        
M05 Cabinet size G, cabinet sealed with baseplate at the bottom  
M05 Cabinet size H, cabinet sealed with baseplate at the bottom  
M05 Cabinet size E, cabinet sealed with baseplate at the bottom  
M05 Cabinet size D, cabinet sealed with baseplate at the bottom  
M05 Cabinet size C, cabinet sealed with baseplate at the bottom  
M05 Cabinet size B, cabinet sealed with baseplate at the bottom  
M05 Cabinet size J, cabinet sealed with baseplate at the bottom  
M23 Cabinet size J, degree of protection IP23      
M23 Cabinet size B, degree of protection IP23      
M23 Cabinet size C, degree of protection IP23      
M23 Cabinet size D, degree of protection IP23      
M23 Cabinet size E, degree of protection IP23      
M23 Cabinet size G, degree of protection IP23      
M23 Cabinet size H, degree of protection IP23      
M43 Cabinet size G, degree of protection IP43      
M43 Cabinet size H, degree of protection IP43      
M43 Cabinet size J, degree of protection IP43      
M43 Cabinet size D, degree of protection IP43      
M43 Cabinet size B, degree of protection IP43      
M43 Cabinet size C, degree of protection IP43      
M43 Cabinet size E, degree of protection IP43      
M70 Cabinet size G, EMC shield for converter output    
M70 Cabinet size H, EMC shield for converter output    
M70 Cabinet size E, EMC shield for converter output    
M70 Cabinet size D, EMC shield for converter output    
M70 Cabinet size C, EMC shield for converter output    
M70 Cabinet size B, EMC shield for converter output    
M70 Cabinet size J, EMC shield for converter output    
M75 Cabinet size J, PE bus        
M75 Cabinet size B, PE bus        
M75 Cabinet size C, PE bus        
M75 Cabinet size D, PE bus        
M75 Cabinet size E, PE bus        
M75 Cabinet size G, PE bus        
M75 Cabinet size H, PE bus        

TAG£º